Page1
DNPH表1
SORBENT TUBE
DNPH Active Sorbent Tube
Active Sorbent Tube for Aldehydes
DNPH Passive Sorbent Tube
DNPH Passive Sorbent Tube for Aldehydes
Page2
DNPH中1
DNPH Active Sorbent Tube
Active Sorbent Tube for Aldehydes
It is ideal for active sampling of aldehydes/ketones in the sorbent tube filled with -
DNPH (2,4 - dinitrophenylhydrazine) impregnated silica gel.
High-accuracy sampling is available, because Sibata items are so produced as to make
low blank value, and the small variation by lot-to-lot, and that in the same lot as well.
Sampling Extraction HPLC Analysis
To connect tube to a mini-pump, Push the solvent with the syringe barrel, To analyze with High Performance
and suck at a constant flow rate and extract the trapped substance. Liquid Chromatography(HPLC)
DNPH Active
Sorbent Tube
Ozone Scrubber
samling pump
■Related Product 【Ozone Scrubber】
Ozone scrubber is a cartridge for removing ozone in the atmosphere. You can remove the ozone by
potassium iodide filled in the cartridge. The ozone will decompose the DNPH derivative.
Please use it when you use the DNPH Active Sorbent Tube in an environment such as an outdoor
where ozone exists.
■Specifications
Name DNPH Active Sorbent Tube Ozone Scrubber
Trapping Substance Aldehydes ,Ketones -
Adsorbent DNPH (2,4 - dinitrophenylhydrazine) impregnated silica gel (350mg)DNPH impregnated amount: about 1mg Potassium iodide
Dimension 43mm ×φ16mm Diameter of suction extraoral: about φ4mm and φ6mm(two stages)
Transportation/Storage Refrigerated transport/Chilled storage -
Expiration date Within one year after production (it is shown on the bag.)
Quantity 10pcs. per aluminum package 10pcs. included
Item code 080150-076 080150-0761
※As the items need refrigeration, shipment of the products will be refrigerated transport.
※Analysis fee is not included in our quotation.
Mini-pump MP-sigma NⅡseries are suggested for sampling.
By selecting a suitable pump for using condition, you can sample at a stable flow rate without
putting an excessive load on the pump.
Sampling flow rate Recommended mini-pump Item code (Main unit only)
0.1 t o 0.5(L/min) Mini-pump, model Sigma 30NⅡ 090860-034
0.3 t o 1.5(L/min) Mini-pump, model Sigma 100HNⅡ 090860-104
Page3
DNPH中2
Main Three Features of
Sibata Products
Low Blank Small Variation Small variation
Value! in the same lot! by lot-to-lot!
nk Valu
e!
a Comparison to
Low Bl Other manufacturers
Cartridge blank value in average
Blank value comparison
Formaldehyde 0.005(μg)
80
Acetaldehyde 0.008(μg)
70
* The values are the results before shipment, and we do not guarantee the values.
60
50
in the sam
e lot! 40
ariation ll V 30Sma 20
Same lot variation comparison 10
0
our company company company company company
50 products A B C D E
Formaldehyde Acetaldehyde
40
SampleA
30 SampleB
SampleC
20 SampleD Same lot variation comparison
SampleE
10
0 80
Formaldehyde Acetaldehyde
70
60
ot-to-lot!
50
40
ll variati
on by l 30
ma 20S 10 our company company company company company
Blank value comparison by lot-to-lot products A B C D E0 Formaldehyde
50
80
40 70
60
lotA
30 lotB 50
lotC 40
20 lotD 30
lotE 20
10 10
0
our company company company company company
0 products A B C D E
Formaldehyde Acetaldehyde Acetaldehyde
The results are from our laboratory test in the year 2012.
blank value(ng/number) blank value(ng/number)
blank value(ng/number)
blank value(ng/number) blank value(ng/number)
Page4
DNPH表4
DNPH Passive Sorbent Tube
DNPH Passive Sorbent Tube for Aldehydes
It is a passive sampler filled with DNPH impregnated silica gel in the diffusion tube.
It is ideal for sampling formaldehyde, acetaldehyde at low blank.
You can connect the tube directly to a syringe at the time of analysis, and the
structure is so designed as allows for easy operation with less extraction loss.
Sampling Extraction HPLC Analysis
Left for 24 hours by setting the holder, Push the solvent with the syringe barrel, You can make injection without pretreatment with
after it is removed from the bag. and extract the trapped substance. High Performance Liquid Chromatography (HPLC)
■Correlation to the active method ■Sampling rate
Formaldehyde Acetaldehyde Substance Unit:μ g/ppm・hr
Formaldehyde 5.1
y=0.99x y=0.93x Acetaldehyde 5.6
R2=0.99 R2=0.99
※Measurement time: 8 to 24 hours
■Options
Name Item code
Holder ( it is commonly used for Aldehyde, Ketones, HCHO, NO ) 080150-06912
Active method(ppm) Active method(ppm) ※It is the same product as current HCHO, NO2 holder.
■Specification
Name DNPH Passive Sorbent Tube
Trapping substances Aldehydes, Ketones
Adsorbent DNPH (2,4 - dinitrophenylhydrazine) impregnated silica gel (200mg)DNPH impregnated amount is about 0.6mg.
Dimension 66mm ×φ10mm
Transportation/Storage Refrigerated transport / Chilled storage
Expiration date Within six months after production (it is shown on the bag.)
Quantity 10pcs. per aluminum bag
Item code 080150-075
※As the items need refrigeration, shipment of the products will be refrigerated transport.
※Analysis fee is not included in our quotation.
Specifications, and appearance described in this document are based on information as of March 25, 2015. They are subject to change without notice for improvement of the product.
1-1-62, Nakane Soka-City, Saitama, Japan
TEL:+81-48-933-1582 FAX:+81-48-933-1591
E-mail:overseas@sibata.co.jp
http://www.sibata.co.jp/english/
Passive method(ppm)
Passive method(ppm)